DualUSB module 5V 18650 lithium batteries overcharge / short circuit protection
DualUSB 5V module for 18650 lithium batteries with overload / short circuit protection
You can pay safely by Card, PayPal, Amazon Pay or Bank Transfer
Express shipments with DHL, BRT, GLS
You have 15 days from delivery to return the product if you are not satisfied
DualUSB 5V module for 18650 lithium batteries with overload / short circuit protection
Features
· Designed for DIY power bank: The 18650 battery needs to be discharged and the length is 65mm. The pointed battery cannot be used. If you are using old batteries, with different capacities, the assembled battery is guaranteed for at least 3.5V per voltage. If the voltage is too low, it will not charge. (Note: It also supports lithium battery, mobile phone battery and tablet battery).
· Supported Connection Methods: Only one lithium battery or multiple lithium batteries can be connected in parallel. The capacity of the connected battery does not exceed 200,000 mA, as long as a battery with a voltage of 3.0-4.2 V can be used. Note: The cable connected to the battery must be short.
· Protection function: The enhanced lithium battery protection circuit has been built in, prevent overcharging, overcharging short-circuit protection, over-current protection and over-temperature protection. Note: The positive pole of the battery is connected to B + and the negative pole is connected to B-, do not reverse it. If it is reversed, it will burn out !!!!
· Charging Cable: Supports charging three USB data cables, also for iPhone and Android.
· Size: 6.5 * 2.5 * 0.1cm; Double output current: 5V 2.4A; Input voltage B + to B-: 3.0 - 4.2V
Technical specifications
· Weight: 10.8 grams
· PCM IR: ≤65mΩ
· 0 V change allowed: Yes
· Constant current: 2.4A
· Double output current: 5V 2.4A
· Input voltage B + to B-: 3.0 - 4.2V
Overload protection
· Detection voltage: 4.20 ± 0.05V
· Release voltage: 4.100 ± 0.05V
· Detection delay time:
Low battery detection
· Detection voltage: 3.0 ± 0.10V
· Release voltage: 3.10 ± 0.10V
· Detection delay time:
Short circuit protection
· Short detection delay:
· Release conditions: cut the load
Normal power consumption
· Normal PCM absorption: max 60uA
· Current standby consumption: max 50uA
Working conditions
· Maximum Continuous Charge / Discharge Current: 1.5 / 2.4A
· Working temperature: -5 ~ 45 ℃